Shenzhen Laesent Technology Co., Ltd.
Main products:Anemometer,EMF Meter,Sound lever meter,CCTV Camera,IP Camera
Products
Contact Us
  • Contact Person : Mr. Lai Steven
  • Company Name : Shenzhen Laesent Technology Co., Ltd.
  • Tel : 86-755-89576335
  • Fax : 86-755-82566735
  • Address : ,,#2922,Guoli Building,2nd Sun Asia Electronic City,Nothern Huaqiang Road,Shenzhen,China
  • Country/Region : China
  • Zip : 518031

Best -Seller TES-3600 3P4W Power Analyzer with Free Shipping

Best -Seller TES-3600 3P4W Power Analyzer with Free Shipping
Product Detailed
3P4W Power Analyzer 1).1P2W,1P3W,3P3W2M & 3P4W Power 2).Data Logging(512KB Memory,20,000 Sets) 3).RS-232 Interface

3P4W Power Analyzer TES-3600

Three Phase Power Analyzer TES-3600
10 Display Easy - to - View LCD Screen. Connectors for 4 Current Sensing Clamps. 1P2W, 1P3W, 3P3W2M & 3P4W Power Measurement. True RMS Sensing. Power KW, KVAR, KVA, PF, θ ,Hz, & Energy KWh, KVARh & KVAh Measurement. Phase sequency indicator function. Backlight display function. Manual Data Memory and Read (99 sets). Data Logging (512KB Memory, 20,000 sets) Programmable Trigger - Points and Start / Stop Time. RS-232 Optical Interface with three phase voltage / current Waveform display and Harmonic analysis. Easy - to - use Push - Button Operation. Light Weight, Portable Design.
Voltage Measurement (V)
Ranges

Method

Accuracy Input impedance
600.0VTrue RMS± 0.5%rdg ± 10dgts (>30V)2M Ω
Current Measurement (A)
Ranges Method Accuracy
250A 500A 1000A

True RMS

± 0.5%rdg ± 10dgts + clamp on sensor specifications

Active Power Measurement (KW)
Ranges

Accuracy

Effect of power factor
600.0KW± 0.5%rdg ± 10dgts + clamp on sensor specifications

± 0.1%rdg

Reactive Power Measurement (KVAR)
Ranges Accuracy Effect of power factor
600.0KVAR± 0.5%rdg ± 10dgts + clamp on sensor specifications± 0.1%rdg
Apparent Power Measurement (KVA)
Ranges Accuracy
600.0KVA± 0.5%rdg ± 10dgts + clamp on sensor specifications
Power Integration Measurement
Power Integration Resolution Accuracy
0.0KWh to 9999MWh0.1KWh± 0.5%rdg ± 10dgts + clamp on sensor specifications
0.0Kvarh to 9999Mvarh0.1Kvarh
0.0KVAh to 9999MVAh0.1KVAh
Frequency Measurement
Ranges Measurement source Accuracy
40Hz to 100HzVoltage U1± 0.5%rdg ± 1dgt
General Specifications
Size 235(L)x116(W)x54(H)mm (9.3"Lx4.6"Wx2.1"H)
Operating Temperature and Humidity 0 to 50 (32 to 122 ) R.H. < 80% non-condensing
Storage Temperature and Humidity - 10 to 60 (14 to 140 ) R.H. < 70% non-condensing
Accessories

1) Instruction manual

2) Software CD Rom / Optical RS-232 interface

3) Deluxe carrying case

4) Battery (AA 1.5V x 8pcs )

5) AC adaptor (110V -> 12V ; 220V -> 12V)

6) 4pcs current clamp transducer (1, 2, 3, 4 cable length 3 meters) (1000A AC, jaw opening 40mm)

7) 4pcs crocodiles test leads (blue, yellow, red, black, wire length 3 meters)